'''PROBLEM 1:''' make sure broadcast is working between 167,68,69,160 subnets, otherwise EPICS will not work; it must be set in BigIron switch | |||
'''PROBLEM 2:''' switches in the hall must have spining tree OFF; it must be set in every Foundry switch | |||
To access switches in the hall use tsconnect; username admin, pass: xxxxxxxx | To access switches in the hall use tsconnect; username admin, pass: xxxxxxxx | ||
Revision as of 15:46, 29 January 2009
PROBLEM 1: make sure broadcast is working between 167,68,69,160 subnets, otherwise EPICS will not work; it must be set in BigIron switch
PROBLEM 2: switches in the hall must have spining tree OFF; it must be set in every Foundry switch
To access switches in the hall use tsconnect; username admin, pass: xxxxxxxx
Commands:
show vlan configure terminal vlan 596 no tagged ethernet 13/1 no untagged ethernet 13/2 vlan 569 untagged ethernet 13/1 untagged ethernet 13/1 to 13/8 exit exit write memory