'''PROBLEM 1:''' make sure broadcast is working between 167,68,69,160 subnets, otherwise EPICS will not work; it must be set in BigIron switch
'''PROBLEM 1:''' make sure broadcast is working between 167,68,69,160 subnets, otherwise EPICS will not work; it must be set in BigIron switch


'''PROBLEM 2:''' switches in the hall must have spining tree OFF; it must be set in every Foundry switch
'''PROBLEM 2:''' switches in the hall must have spanning tree OFF; it must be set in every Foundry switch


To access switches in the hall use tsconnect; username admin, pass: xxxxxxxx
To access switches in the hall use tsconnect; username admin, pass: xxxxxxxx

Revision as of 17:51, 29 January 2009

PROBLEM 1: make sure broadcast is working between 167,68,69,160 subnets, otherwise EPICS will not work; it must be set in BigIron switch

PROBLEM 2: switches in the hall must have spanning tree OFF; it must be set in every Foundry switch

To access switches in the hall use tsconnect; username admin, pass: xxxxxxxx

Commands:

show vlan
configure terminal
vlan 596
  no tagged ethernet 13/1
  no untagged ethernet 13/2
vlan 569
  untagged ethernet 13/1
  untagged ethernet 13/1 to 13/8
exit
exit
write memory