Foundry Switches: Difference between revisions
No edit summary |
No edit summary |
||
(5 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
== BigIron RX-8 == | |||
Main clon cluster switch located in counting room. Inventory number: F423964, p/n: BI-RX-8-AC, s/n: SA29085027. | |||
== general information == | |||
'''PROBLEM 1:''' make sure broadcast is working between 167,68,69,160 subnets, otherwise EPICS will not work; it must be set in BigIron switch | '''PROBLEM 1:''' make sure broadcast is working between 167,68,69,160 subnets, otherwise EPICS will not work; it must be set in BigIron switch | ||
'''PROBLEM 2:''' switches in the hall must have spanning tree OFF; it must be set in every Foundry switch | '''PROBLEM 2:''' switches in the hall must have spanning tree OFF; it must be set in every Foundry switch. | ||
To access switches normally goto clon10/clon00 and do ''ssh boiarino@<switch_ip_name>'', use 'boiarino's pass. Then type 'enable' and use pin and hardkey pin. | |||
To access switches in the hall | To access switches in the hall using tsconnect: the same passwords (?). | ||
'''VLAN change''' | |||
show vlan | show vlan | ||
Line 11: | Line 20: | ||
vlan 596 | vlan 596 | ||
no tagged ethernet 13/1 | no tagged ethernet 13/1 | ||
no untagged ethernet 13/2 | no untagged ethernet 13/2 to 13/8 | ||
vlan 569 | vlan 569 | ||
tagged ethernet 13/1 | |||
untagged ethernet 13/ | untagged ethernet 13/2 to 13/8 | ||
exit | exit | ||
exit | exit | ||
write memory | write memory | ||
'''Who is connected''' | |||
List of all ports currently active: | |||
show int | include is up | |||
Get MAC address(es) of all devices connected to the particular port: | |||
show mac-ad | include 3/17 | |||
Get IP address for particular MAC address: | |||
show arp mac 0006.5b49.8ef6 | |||
Get full table of IP addresses, MAC addresses and port numbers: | |||
show arp | |||
The same for particular IP address: | |||
show arp | include xxx.xxx.xxx.xxx |
Latest revision as of 14:18, 20 February 2009
BigIron RX-8
Main clon cluster switch located in counting room. Inventory number: F423964, p/n: BI-RX-8-AC, s/n: SA29085027.
general information
PROBLEM 1: make sure broadcast is working between 167,68,69,160 subnets, otherwise EPICS will not work; it must be set in BigIron switch
PROBLEM 2: switches in the hall must have spanning tree OFF; it must be set in every Foundry switch.
To access switches normally goto clon10/clon00 and do ssh boiarino@<switch_ip_name>, use 'boiarino's pass. Then type 'enable' and use pin and hardkey pin.
To access switches in the hall using tsconnect: the same passwords (?).
VLAN change
show vlan configure terminal vlan 596 no tagged ethernet 13/1 no untagged ethernet 13/2 to 13/8 vlan 569 tagged ethernet 13/1 untagged ethernet 13/2 to 13/8 exit exit write memory
Who is connected
List of all ports currently active:
show int | include is up
Get MAC address(es) of all devices connected to the particular port:
show mac-ad | include 3/17
Get IP address for particular MAC address:
show arp mac 0006.5b49.8ef6
Get full table of IP addresses, MAC addresses and port numbers:
show arp
The same for particular IP address:
show arp | include xxx.xxx.xxx.xxx