CMON

From CLONWiki
Jump to navigation Jump to search

CMON is CLAS Online Data Monitoring program. It does real time event reconstruction using old 'sda' program rewritten to C and modified for multithreaded environment.

Calibration Constants

Calibration constants are stored in offline database. It can be accessed at this link.

Currently calibration constants must be extracted from offline database and stored in a form of files to be used by CMON. It is done using following procedure:

caldb_show_constants_run.pl s=TAG_CALIB ss=tag_t i=ci r=40000 > /home/boiarino/z123

To white it back remove two first lines and type (DO NOT DO THAT!!!):

caldb_write_and_link.pl s=TAG_CALIB ss=tag_t i=ci min=40000 max=50000 ci="test1" f=/home/boiarino/z123

To extract information from database to maps, goto $CLON_PARMS/cmon/Maps and run

db2clonmap.pl system=TAG_CALIB runMin=1 runMax=1000000

it will create subdirectory Maps_1-1000000, 'TAG_CALIB.map' inside and fill it up.