Clon01
Data Mover (move2silo, EPICS)
SUN Blade 2000, 2x900MHz Ultra SPARC-IIIi, 2GB RAM ---+ CLON01
This is *Sun Blade 2000* dual CPU (SPARC IIIi) server which primary use in the *CLAS DAQ is Data Mover*. The secondary use of it is *EPICS* visualisation workstation.
This server runs also
* VERITAS Cluster Server * NIS Slave Server * INGRES Server * CLON Printer Server (for CLONHP and CLONHP2 printers)
---++ Data Mover Location: /usr/local/system/raid
Program: move2silo
Logs: logs/
To start it manually:
[root@clon01]$ cd /ssa [root@clon01]$ mv presilo1 gopresilo [root@clon01]$ move2silo >& /dev/null &
To move Data Mover to *CLON10* edit file */usr/local/system/raid/checkraid* uncommenting corresponding line:
... # for CLON10 # /usr/local/system/raid/move2silo >& /usr/local/system/raid/log & # for CLON01 rsh clon01 /usr/local/system/raid/move2silo ">&" /usr/local/system/raid/log "&" ...
---++ Memory Monitoring Tool *CEDIAG*
location: /opt/SUNWcest/bin/cediag
[root@clon01 ~]$ cediag cediag: Revision: 1.78 @ 2005/02/11 15:54:29 UTC cediag: Analysed System: SunOS 5.8 with KUP 117350-06 (MPR active) cediag: Pages Retired: 0 (0.00%) cediag: findings: 0 datapath fault message(s) found cediag: findings: 0 UE(s) found - there is no rule#3 match cediag: findings: 0 DIMMs with a failure pattern matching rule#4 cediag: findings: 0 DIMMs with a failure pattern matching rule#5