DAQ/Online Quick Reference
DAQ Recovery Procedure
In most cases DAQ will crash because of ROC problem. Do following:
- click 'End Run' or 'Abort', whatever button is active
- click 'Cancel' and then 'Reset'
- go to 'ET_TERM' window, Ctrl-C and run previous command using arrow up (command is 'coda_eb ...')
- run 'roc_status' command from clon10 window; it will show troubled ROC(s) as 'UNDEFINED' or 'active'
- reboot troubled ROC(s) using command 'roc_reboot <roc>' from clon10 window
- wait 2 minutes and run 'roc_status' again; rebooted ROC(s) must be in 'booted' stage
- start new run from 'Download'
IF starting everything from scratch (normally after cluster reboot or other major disasters):
- on clon10 as root start msql database daemon (should be done automatically, not yet)
- on clon10 as clasrun start SmartSockets rtserver
DAQ procedures
To start all DAQ processes goto clon10 as clasrun and type
daq_start this
to open all windows on current workspace. If daq_start executed without parameter, it will open everything on clon03's bottom screen on currently active workspace.
To kill all DAQ processes goto clon10 as clasrun and type
daq_exit
Online procedures
To start online monitoring processes use following commands:
mon_start mon1_start mon2_start
they will start everything on clon00, clonmon1 and clon04 respectively.
To kill online monitoring processes use following commands:
mon_exit mon1_start mon2_start
Occupancy plots must be started on clonmon1. Login as clasrun and type
monb
Background information
- CRON JOBS: on clon10, clon00, clon01 and clondb1 make sure cron jobs are running (they must start automatically after reboot); if have to start cron jobs, login as clascron to the mentioned machines, goto directory /home/clascron/backup and follow instructions in README file, normally it will be following:
login as 'clascron' to the clon10 goto /home/clascron/backup type 'crontab -l' to see what is running type 'crontab -r' to erase all existing cron jobs type 'crontab clon10' repeat everything for clon00 and clon01, using file 'clon00' and 'clon01' respectively
Sometimes you may want to turn some cron jobs off to avoid alarms during system reconfiguration: do not forget to turn them on again after you are done !
- Process management: SmartSockets-based process management procedures must be started as clasrun using following command:
control_process_manager start clasprod clasprod control_procmgr_manager start clasprod clasprod control_ipc_process_manager start clasprod clasprod
and killed by following:
control_process_manager stop clasprod clasprod control_procmgr_manager stop clasprod clasprod control_ipc_process_manager stop clasprod clasprod