2. DAQ high event rate test: 60kHz random pulser tests were conducted with different subsets of crates; FADCs are working fine; DCRB after firmware upgrade to version 1.5 are working fine as well; some crates with CAEN TDCs (tdcftof's) shows problems in TI readout but it looks like induced by CAEN TDCs and depends on trigger rule 1 settings, study will be continued; VTP readout will be checked as well | 2. DAQ high event rate test: 60kHz random pulser tests were conducted with different subsets of crates; FADCs are working fine; DCRB after firmware upgrade to version 1.5 are working fine as well; some crates with CAEN TDCs (tdcftof's) shows problems in TI readout but it looks like induced by CAEN TDCs and depends on trigger rule 1 settings, study will be continued; VTP readout will be checked as well | ||
3. Preparation for upcoming run: cosmic data being taken occasionally using PROD66 configuration to check various detectors, so far everything works; Sergey is updating daq expert documentation and will work with Rafo to introduce him to daq operations | 3. Preparation for upcoming run: cosmic data being taken occasionally using PROD66 configuration to check various detectors, so far everything works; Sergey is updating daq expert documentation and will work with Rafo to introduce him to daq operations; htcc (and any other calibration runs) have to be coordinated with Mohammad | ||
Other issues discussed: | Other issues discussed: |
Revision as of 10:55, 29 July 2020
present: Sergey, vpk, rafo, Raffaella, nathan, Stepan, pasyuk, cuevas
1. Trigger upgrade progress: drift chamber - Rafo/Sergey
2. DAQ high event rate test: 60kHz random pulser tests were conducted with different subsets of crates; FADCs are working fine; DCRB after firmware upgrade to version 1.5 are working fine as well; some crates with CAEN TDCs (tdcftof's) shows problems in TI readout but it looks like induced by CAEN TDCs and depends on trigger rule 1 settings, study will be continued; VTP readout will be checked as well
3. Preparation for upcoming run: cosmic data being taken occasionally using PROD66 configuration to check various detectors, so far everything works; Sergey is updating daq expert documentation and will work with Rafo to introduce him to daq operations; htcc (and any other calibration runs) have to be coordinated with Mohammad
Other issues discussed:
- Eugene Pasyuk will run 2 cables from Moller to BAND crate to use 2 FADC channels in standalone Moller setup, in a future we may consider designated crate
- Sergey will double check daq settings in upcoming run trigger files
- Chris will work out VXS backplane order