present: Sergey Boyarinov, Valery, Rafo, Cole, Raffaella
present: Sergey Boyarinov, Valery, Rafo, Cole, Raffaella, Ben, Stepan, Nathan, Pasyuk


1. DAQ/Trigger:
1. DAQ/Trigger:
Line 5: Line 5:
* what is ready: PROD config contains 'almost' everything (all VME crates, FC VTP boards), run with 60KHz random pulser and block_level=40, got 16kHz/200MByte/sec
* what is ready: PROD config contains 'almost' everything (all VME crates, FC VTP boards), run with 60KHz random pulser and block_level=40, got 16kHz/200MByte/sec


* what is missing:
* what is missing: scaler1 crate commissioning, Stepan will help with helicity signals, will do it after meeting;, 1KHz will be connected to TS, readout scaler1 only on corresponding event type; check faraday etc are connected
 
* one FTOF VTP is missing, may take one from CND
 


2. DAQ and Trigger commissioning plans
2. DAQ and Trigger commissioning plans


* DAQ
* DAQ: rols info - text, histos; test subset of ROCs separately for performance purposes; check if all data in data stream, EPICS and RCDB; test mode 7 at some point


* Trigger
* Trigger: offline reconstruction must be running (all trig banks); <det>mon has pulse histogram, will be running from 1 trigger bit and set timing; delay scan using scalers will be done; cluster energy histogram to control energy threshold, Cole knows scale from cosmic; run with different conditions and record data for offline analysis, will prepare trigger config file for every trigger setting

Revision as of 10:51, 29 November 2017

present: Sergey Boyarinov, Valery, Rafo, Cole, Raffaella, Ben, Stepan, Nathan, Pasyuk

1. DAQ/Trigger:

  • what is ready: PROD config contains 'almost' everything (all VME crates, FC VTP boards), run with 60KHz random pulser and block_level=40, got 16kHz/200MByte/sec
  • what is missing: scaler1 crate commissioning, Stepan will help with helicity signals, will do it after meeting;, 1KHz will be connected to TS, readout scaler1 only on corresponding event type; check faraday etc are connected
  • one FTOF VTP is missing, may take one from CND


2. DAQ and Trigger commissioning plans

  • DAQ: rols info - text, histos; test subset of ROCs separately for performance purposes; check if all data in data stream, EPICS and RCDB; test mode 7 at some point
  • Trigger: offline reconstruction must be running (all trig banks); <det>mon has pulse histogram, will be running from 1 trigger bit and set timing; delay scan using scalers will be done; cluster energy histogram to control energy threshold, Cole knows scale from cosmic; run with different conditions and record data for offline analysis, will prepare trigger config file for every trigger setting