* Hall D test setup runs well, they are fixing FADC etc bugs | * Hall D test setup runs well, they are fixing FADC etc bugs | ||
* DVCS: GUI had a bug - fixed; tcpServer server bug - fixed temporary, permanent solution is needed; Ben is tuning cables, will be ready for installation in the Hall today; temperature control: NI control device shows some trouble, FX is debugging, clonwin3 is installed and ready; Nerses will port jlab discr on vxWorks, Sergey will provide mv2432 CPU | * DVCS: GUI had a bug - fixed; tcpServer server bug - fixed temporary, permanent solution is needed; Ben is tuning cables, will be ready for installation in the Hall today; temperature control: NI control device shows some trouble, FX is debugging, clonwin3 is installed and ready; Nerses will port jlab discr on vxWorks, Sergey will provide mv2432 CPU; FX took pedestal run and we have beam data; with current CLAS trigger almost no useful events, we need DVCS trigger input; we have 8 dead channels and 10 noisy channels, and some channels (25) have pedestal problem |
Revision as of 10:31, 7 December 2011
present: Sergey Boyarinov, Sergey Pozdnyakov, FX, Nerses
1. g14b: L1 was 16KHz, now 11kHz after yesterday fixes in TOF, accepted rate 4kHz, L2 accepts 30%, livetime aroun 83%; L2RESET need check; fans replacemnt continues, 7 more fastbus crates to go; Franz is working on helicity correction; occupancy control program will be tested
2. Test setups:
- DCRB test: got 20Mevents, will analyze
- Hall D test setup runs well, they are fixing FADC etc bugs
- DVCS: GUI had a bug - fixed; tcpServer server bug - fixed temporary, permanent solution is needed; Ben is tuning cables, will be ready for installation in the Hall today; temperature control: NI control device shows some trouble, FX is debugging, clonwin3 is installed and ready; Nerses will port jlab discr on vxWorks, Sergey will provide mv2432 CPU; FX took pedestal run and we have beam data; with current CLAS trigger almost no useful events, we need DVCS trigger input; we have 8 dead channels and 10 noisy channels, and some channels (25) have pedestal problem