CAEN V1290: Difference between revisions
Jump to navigation
Jump to search
Line 18: | Line 18: | ||
TDCs were in slots 7, 8, 9, 10 correspondingly: | TDCs were in slots 7, 8, 9, 10 correspondingly: | ||
[https://clonwiki.jlab.org/wiki/clondocs/Docs/tdc1290/1290.Ser.56.60.53.55_10491.pdf] | [https://clonwiki.jlab.org/wiki/clondocs/Docs/tdc1290/1290.Ser.56.60.53.55_10491.pdf 1290.Ser.56.60.53.55_10491.pdf] | ||
[https://clonwiki.jlab.org/wiki/clondocs/Docs/tdc1290/1290.Ser.56.60.53.55_10491.ps] | [https://clonwiki.jlab.org/wiki/clondocs/Docs/tdc1290/1290.Ser.56.60.53.55_10491.ps 1290.Ser.56.60.53.55_10491.ps] | ||
Revision as of 16:15, 4 October 2011
Manual (pdf)
Test results : Calibration with DSC2
TDC Outputs from JLAB VME Discriminators DSC2 was an Input for CAEN VX1290A.
Width of TDC Outputs changed from 4 ns to 40 ns.
Histograms present distributions for four CAEN VX1290A TDCs in each run
Test was done in Counting room VME crate "croctest2"
In run # 10491 four VX1290A with Ser. ## 56, 60, 53, 55 were tested,
TDCs were in slots 7, 8, 9, 10 correspondingly:
1290.Ser.56.60.53.55_10491.pdf 1290.Ser.56.60.53.55_10491.ps
1290.Ser.56.60.53.55_10491.pdf 1290.Ser.56.60.53.55_10491.ps
- FADC250 Signal: one channel - 100 events; width because of trigger jitter ?
fadc250.SB.doublepeak.pdf ( pdf)
- FADC250 Signal: one channel - one event
fadc250.SB.onepeak.pdf ( pdf)