December 15, 2010 online meeting minutes: Difference between revisions

From CLONWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 7: Line 7:
* Ben's trigger GUI is working; v1495 software was adjusted; EPICS scalers readout to be implemented
* Ben's trigger GUI is working; v1495 software was adjusted; EPICS scalers readout to be implemented


* DAQ was tuned; both rol2 and net are running on all available co-processors; 'parallel' rol1 is used everywhere; reached 4.6kHz at 86% livetime, limited by DC occupancy but DAQ limit is close as well; sc2 rol1 processing time is much bigger then others (see xxx); clastrig2 readout speed still to be studied  
* DAQ was tuned; both rol2 and net are running on all available co-processors; 'parallel' rol1 is used everywhere; reached 4.6kHz at 86% livetime and beam current 140nA, limited by DC occupancy but DAQ limit is close as well; sc2 rol1 processing time is much bigger then others (see xxx); clastrig2 readout speed still to be studied  


* RF signal dissapeards, Raffaella fixed it (bad unit, see logbook Dec 14 around 7pm), need to fix permanently
* RF signal dissapeards, Raffaella fixed it (bad unit, see logbook Dec 14 around 7pm), need to fix permanently

Revision as of 10:28, 15 December 2010

present: Sergey Boyarinov, Sergey Pozdnyakov

1. TPE run status

  • new trigger was commissioned and compared with old one, seems working, need to measure adc gate position; latch feature seems working, need to read it out and place to datastream
  • Ben's trigger GUI is working; v1495 software was adjusted; EPICS scalers readout to be implemented
  • DAQ was tuned; both rol2 and net are running on all available co-processors; 'parallel' rol1 is used everywhere; reached 4.6kHz at 86% livetime and beam current 140nA, limited by DC occupancy but DAQ limit is close as well; sc2 rol1 processing time is much bigger then others (see xxx); clastrig2 readout speed still to be studied
  • RF signal dissapeards, Raffaella fixed it (bad unit, see logbook Dec 14 around 7pm), need to fix permanently
  • last night 2 switches went down, CC want to replace the one on 96 subnet, should think about bethsw3sc; also, dc6pmc1 died and did not want to reboot
  • two kind of ROC crashes were observed: ROLS_LOOP on host and PROC on PMCs; last one does not require reboot, cancel-reser-download-.. works, first one will try it; will try to reproduce and debug it over downtime (big buffer check function etc)
  • TOF SCHV alarm did not work when all values (except EPICS demand values) went to zero; crate turned on but values stayed zero and it was no alarm which is correct; we do not know why values went down to zero; will ask Nerses to look