December 12, 2007 online meeting minutes: Difference between revisions

From CLONWiki
Jump to navigation Jump to search
Boiarino (talk | contribs)
No edit summary
Boiarino (talk | contribs)
No edit summary
Line 1: Line 1:
present: Sergey Boyarinov, Sergey Pozdnyakov, Nerses Gevorgyan, Eugene Pasyuk, Hovanes Egiyan, Vitaly Baturin
present: Sergey Boyarinov, Sergey Pozdnyakov, Nerses Gevorgyan, Eugene Pasyuk, Hovanes Egiyan, Vitaly Baturin


1. G9A run status
'''G9A run status'''


* Lecroy 2313 discr replacements: RF (1), TOF (2 from new TOF counters)
* Lecroy 2313 discr replacements: RF (1), TOF (2 from new TOF counters)
Line 19: Line 19:
* clon02 key board speaker died ? somebody switched to internal spiker
* clon02 key board speaker died ? somebody switched to internal spiker


2. Projects review:
'''Projects review'''


- CLAS12 trigger: Ben and Sergey are working on level1 (EC clusters); may test next year on real calorimeters
- CLAS12 trigger: Ben and Sergey are working on level1 (EC clusters); may test next year on real calorimeters

Revision as of 23:02, 17 December 2007

present: Sergey Boyarinov, Sergey Pozdnyakov, Nerses Gevorgyan, Eugene Pasyuk, Hovanes Egiyan, Vitaly Baturin

G9A run status

  • Lecroy 2313 discr replacements: RF (1), TOF (2 from new TOF counters)

repair status: 5 2313, 5 HV boards, usually takes about month need JLAB discr: James may do that in a few month, need official arrangement, James or Chris will do that, Sergey will talk to Volker again

  • RF monitoring was improved in PAW monitoring
  • few broken LAC HV boards to be repaired, we'll send and Italians will pay
  • Jerry built online recsis, it runs but crashes and it does not fill occupancy plots, work in progress
  • h2root to clonmon
  • clasweb: restarted httpd and tomcat to fix; next time may look at log file, ask CC to do that
  • clon02 key board speaker died ? somebody switched to internal spiker

Projects review

- CLAS12 trigger: Ben and Sergey are working on level1 (EC clusters); may test next year on real calorimeters

- EPICS: Lecroy HV support was implemented in 3.14 and under testing in classc0 test setup, now we have both CAENs and Lecroy HV implemented, as well as HallSystems

separate alarms will be generated for test setup (Nerses)

medm hist problem: sciplot does not support filled hists, xrtgraf do it but need license, Nerses is working

TO DO: use standard iocCore instead of custom ones as it is done now

cleanup: restored, old epics

CAMAC in progress,

medm, edm, ...

- BONUS readout

PCI TI board is in progress by Ben (will be PCI, not PCI-X, so we need PC with both), we have a list of equipment needed, will buy it shortly after making sure we have necessary software support, mail Abbott about it

- electronics inventory db

Sergey P. is filling up database, in a meanwhile we can start to implement notification scripts, for example 'repair status' and 'spare status'; also need procedure scripts, for example found spare module, replace module etc; need web frontend (student job ?); need history !!! (if line changed, create new line, preserve existing one)

standard operations (queries):

 - search for board type, repair status etc with sorting
 - replacement procedure
 - repair procedure
 - new electronics inserts (status 'ordered', ..)
 - decommission items
  ..............

will search for existing soft, and make a list of operations we want to have

- on Vitaly's request we'll order equipment for CLAS12 central TOF test setup; Sergey will make PR, Vitaly talk to Volker