November 10, 2010 online meeting minutes: Difference between revisions

From CLONWiki
Jump to navigation Jump to search
No edit summary
 
No edit summary
Line 1: Line 1:
present: Sergey Boyarinov, Eugene, Ben, Puneet, Larry, Robert Bennett, Chris Cuevas
present: Sergey Boyarinov, Eugene, Ben, Puneet, Larry, Robert Bennett, Chris Cuevas, Sergey Pozdnyakov


* Level2: will try to use forward dc only (45 deg) if possible, or whole range in opposite sectors; will test if 45 deg can be done; algorithm: 3 wires out 4x6 area means segment
* Level2: will try to use forward dc only (45 deg) if possible, or whole range in opposite sectors; will test if 45 deg can be done; algorithm: 3 wires out 4x6 area means segment
Line 5: Line 5:
* level1 will be redesigned to acomodate 3 TOF areas as separate inputs (by Ben)
* level1 will be redesigned to acomodate 3 TOF areas as separate inputs (by Ben)


*
* rlComment: chicane polarity ? see next item
 
* run_log_begin: new columns in database, Puneet will create list of new channels, Sergey will update db, run_log_begin and rlComment
 
* epics_server config file: Puneet will see what is missing and tell Nerses and Sergey
 
* Calorimeter: 31 ADCs, 31TDCs, 1 trigger (NIM), EPICS scalers, DAQ scalers (gated and ungated)
 
* Gamma profiler (dence fiber monitor): 128TDCs, EPICS scalers
 
* Spars Fiber Monitor (Space frame): EPICS scalers
 
* LAC: need to restore TDC part (optional)
 
* 2 quartz monitors (Space Frame): 2 EPICS scaler channels
 
* occupancy plots for new calorimeter (Eugene, Puneet)
 
* new EPICS GUIs: Nerses
 
* new BOS banks: Sergey
 
* in commissioning: cosmic run with new calorimeter located vertically

Revision as of 10:00, 10 November 2010

present: Sergey Boyarinov, Eugene, Ben, Puneet, Larry, Robert Bennett, Chris Cuevas, Sergey Pozdnyakov

  • Level2: will try to use forward dc only (45 deg) if possible, or whole range in opposite sectors; will test if 45 deg can be done; algorithm: 3 wires out 4x6 area means segment
  • level1 will be redesigned to acomodate 3 TOF areas as separate inputs (by Ben)
  • rlComment: chicane polarity ? see next item
  • run_log_begin: new columns in database, Puneet will create list of new channels, Sergey will update db, run_log_begin and rlComment
  • epics_server config file: Puneet will see what is missing and tell Nerses and Sergey
  • Calorimeter: 31 ADCs, 31TDCs, 1 trigger (NIM), EPICS scalers, DAQ scalers (gated and ungated)
  • Gamma profiler (dence fiber monitor): 128TDCs, EPICS scalers
  • Spars Fiber Monitor (Space frame): EPICS scalers
  • LAC: need to restore TDC part (optional)
  • 2 quartz monitors (Space Frame): 2 EPICS scaler channels
  • occupancy plots for new calorimeter (Eugene, Puneet)
  • new EPICS GUIs: Nerses
  • new BOS banks: Sergey
  • in commissioning: cosmic run with new calorimeter located vertically