Line 15: | Line 15: | ||
preferabley deadtimeless, but can be with dead timne like clas trigger scalers; | preferabley deadtimeless, but can be with dead timne like clas trigger scalers; | ||
readout every 10 seconds, 32 bit registers but probably less bit actual count | readout every 10 seconds, 32 bit registers but probably less bit actual count | ||
discriminator test input allows to mask outputs | |||
We will install everything in the hall and set all software by the end of next week (before Sergey B. vacation), | |||
communication between Ben's machine and crates in the hall will be established similarly to clastrig2; | |||
next week 7 v1495's will be moved to the hall | |||
cabling will be done then | |||
communication to FC still must be tested: will ask Chris |
Revision as of 09:42, 16 July 2008
present: Sergey Boyarinov, Ben Raydo, Sergey Pozdnyakov
clock 15ns, propagation time 65-90ns, including hodoscope (15ns come from passing data between v1495 boards)
discr width 7-43ns
inputs to v1495: common delay for hodoscope with 5ns step
need matching table between hodoscope and calorimeter !!!
photon and electron triggers in parallel: may increase total trigger timing
scalers will be implemented to all inputs, and some trigger results, resolution about 25MHz; preferabley deadtimeless, but can be with dead timne like clas trigger scalers; readout every 10 seconds, 32 bit registers but probably less bit actual count
discriminator test input allows to mask outputs
We will install everything in the hall and set all software by the end of next week (before Sergey B. vacation), communication between Ben's machine and crates in the hall will be established similarly to clastrig2;
next week 7 v1495's will be moved to the hall
cabling will be done then