We discussed CLAS12 trigger layout and how new Fast Electronics Group boards developed for Hall D can be fitted into CLAS12 environment. | We discussed CLAS12 trigger layout and how new Fast Electronics Group boards developed for Hall D can be fitted into CLAS12 environment. | ||
Channel count was converted to the actual number of boards and crates. | |||
Following table contains channel count for FADCS and their VXS crate layout: | Following table contains channel count for FADCS and their VXS crate layout: | ||
Line 21: | Line 22: | ||
TDC channel counts is the same, CAEN v1190/v1290 boards will be used; the number of boards: | TDC channel counts is the same, CAEN v1190/v1290 boards will be used; the number of boards: | ||
v1190: 2940 channels, 127 per board -> 24 boards | v1190: 2940 channels, 127 per board -> 24 boards, have more then 30 already | ||
v1290: 784 channels, 31 per board -> 26 boards | v1290: 784 channels, 31 per board -> 26 boards, have 8 already, with spares need at least 20 boards | ||
JLAB discriminators: 3724 channels, 16 per board -> 233 boards | JLAB discriminators: 3724 channels, 16 per board -> 233 boards, with spares 240 boards |
Revision as of 23:38, 22 April 2008
present: Sergey Boyarinov, Chris Cuevas, Ben Raydo, Sergey Pozdnyakov
We discussed CLAS12 trigger layout and how new Fast Electronics Group boards developed for Hall D can be fitted into CLAS12 environment. Channel count was converted to the actual number of boards and crates.
Following table contains channel count for FADCS and their VXS crate layout:
VXS1: EC: 36x6=216 per sector, 1296 total (7 FADCs on left side of VXS, 7 on right, 8 channels unused) VXS2: PEC: 64x3=192 per sector, 1152 total (8 FADCs on left side of VXS, 4 on right, no channels unused) VXS3: TOF: 114 per sector, 684 total (8 FADCs on left side of VXS, 14 channels unused) SC: 56 per sector, 336 total, CC: 18 per sector, 108 total (5 FADCs on right side of VXS, 6 channels unused) VXS19: HTCC: 48 total (3 FADCs on left side of VXS, no channels unused) CTOF: 100 total (7 FADCs on right side of VXS, 12 channels unused) Total: 3724 channels, 244 FADCs (140 channels unused - 8.75 boards), 19 VXS crates With spares and test setup: 250 FADC boards, 21 VXS crates
TDC channel counts is the same, CAEN v1190/v1290 boards will be used; the number of boards:
v1190: 2940 channels, 127 per board -> 24 boards, have more then 30 already v1290: 784 channels, 31 per board -> 26 boards, have 8 already, with spares need at least 20 boards
JLAB discriminators: 3724 channels, 16 per board -> 233 boards, with spares 240 boards