Line 7: | Line 7: | ||
VXS1: EC: 36x6=216 per sector, 1296 total (7 FADCs on left side of VXS, 7 on right, 8 channels unused) | VXS1: EC: 36x6=216 per sector, 1296 total (7 FADCs on left side of VXS, 7 on right, 8 channels unused) | ||
VXS2: PEC: 64x3=192 per sector, 1152 total (8 FADCs on left side of VXS, 4 on right, no unused) | VXS2: PEC: 64x3=192 per sector, 1152 total (8 FADCs on left side of VXS, 4 on right, no channels unused) | ||
VXS3: TOF: 114 per sector, 684 total (8 FADCs on left side of VXS, 14 channels unused) | VXS3: TOF: 114 per sector, 684 total (8 FADCs on left side of VXS, 14 channels unused) | ||
SC: 56 per sector, 336 total, | SC: 56 per sector, 336 total, | ||
CC: 18 per sector, 108 total (5 FADCs on right side of VXS, 6 channels unused) | CC: 18 per sector, 108 total (5 FADCs on right side of VXS, 6 channels unused) | ||
VXS19: HTCC: 48 total (3 FADCs on left side of VXS, no channels unused) | |||
CTOF: 100 total (7 FADCs on right side of VXS, 12 channels unused) | |||
Total: 3724 channels, 244 FADCs (140 channels unused - 8.75 boards), 19 VXS crates | |||
With spares and test setup: 250 FADC boards, 21 VXS crates |
Revision as of 23:28, 22 April 2008
present: Sergey Boyarinov, Chris Cuevas, Ben Raydo, Sergey Pozdnyakov
We discussed CLAS12 trigger layout and how new Fast Electronics Group boards developed for Hall D can be fitted into CLAS12 environment.
Following table contains channel count for FADCS and their VXS crate layout:
VXS1: EC: 36x6=216 per sector, 1296 total (7 FADCs on left side of VXS, 7 on right, 8 channels unused) VXS2: PEC: 64x3=192 per sector, 1152 total (8 FADCs on left side of VXS, 4 on right, no channels unused) VXS3: TOF: 114 per sector, 684 total (8 FADCs on left side of VXS, 14 channels unused) SC: 56 per sector, 336 total, CC: 18 per sector, 108 total (5 FADCs on right side of VXS, 6 channels unused) VXS19: HTCC: 48 total (3 FADCs on left side of VXS, no channels unused) CTOF: 100 total (7 FADCs on right side of VXS, 12 channels unused) Total: 3724 channels, 244 FADCs (140 channels unused - 8.75 boards), 19 VXS crates With spares and test setup: 250 FADC boards, 21 VXS crates