November 10, 2010 online meeting minutes: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(One intermediate revision by one other user not shown) | |||
Line 1: | Line 1: | ||
present: Sergey Boyarinov, Eugene, Ben, Puneet, Larry, Robert Bennett, Chris Cuevas | present: Sergey Boyarinov, Eugene, Ben, Puneet, Larry, Robert Bennett, Chris Cuevas, Sergey Pozdnyakov | ||
* Level2: will try to use forward dc only (45 deg) if possible, or whole range in opposite sectors; will test if 45 deg can be done; algorithm: 3 wires out 4x6 area means segment | * Level2: will try to use forward dc only (45 deg) if possible, or whole range in opposite sectors; will test if 45 deg can be done; algorithm: 3 wires out 4x6 area means segment | ||
Line 5: | Line 5: | ||
* level1 will be redesigned to acomodate 3 TOF areas as separate inputs (by Ben) | * level1 will be redesigned to acomodate 3 TOF areas as separate inputs (by Ben) | ||
* | * rlComment: chicane polarity ? see next item | ||
* run_log_begin: new columns in database, Puneet will create list of new channels, Sergey will update db, run_log_begin and rlComment | |||
* epics_server config file: Puneet will see what is missing and tell Nerses and Sergey | |||
* Calorimeter: 31 ADCs, 31TDCs, 1 trigger (NIM), EPICS scalers, DAQ scalers (gated and ungated) | |||
* Gamma profiler (dense fiber monitor): 128TDCs, EPICS scalers | |||
* Spars Fiber Monitor (Space frame): EPICS scalers | |||
* LAC: need to restore TDC part (optional) | |||
* 2 quartz monitors (Space Frame): 2 EPICS scaler channels | |||
* occupancy plots for new calorimeter (Eugene, Puneet) | |||
* new EPICS GUIs: Nerses | |||
* new BOS banks: Sergey | |||
* in commissioning: cosmic run with new calorimeter located vertically |
Latest revision as of 16:02, 12 November 2010
present: Sergey Boyarinov, Eugene, Ben, Puneet, Larry, Robert Bennett, Chris Cuevas, Sergey Pozdnyakov
- Level2: will try to use forward dc only (45 deg) if possible, or whole range in opposite sectors; will test if 45 deg can be done; algorithm: 3 wires out 4x6 area means segment
- level1 will be redesigned to acomodate 3 TOF areas as separate inputs (by Ben)
- rlComment: chicane polarity ? see next item
- run_log_begin: new columns in database, Puneet will create list of new channels, Sergey will update db, run_log_begin and rlComment
- epics_server config file: Puneet will see what is missing and tell Nerses and Sergey
- Calorimeter: 31 ADCs, 31TDCs, 1 trigger (NIM), EPICS scalers, DAQ scalers (gated and ungated)
- Gamma profiler (dense fiber monitor): 128TDCs, EPICS scalers
- Spars Fiber Monitor (Space frame): EPICS scalers
- LAC: need to restore TDC part (optional)
- 2 quartz monitors (Space Frame): 2 EPICS scaler channels
- occupancy plots for new calorimeter (Eugene, Puneet)
- new EPICS GUIs: Nerses
- new BOS banks: Sergey
- in commissioning: cosmic run with new calorimeter located vertically