present: Sergey Boyarinov, Benjamin Raydo, Sergey Pozdnyakov | present: Sergey Boyarinov, Benjamin Raydo, Sergey Pozdnyakov, Stepan, Valery, Nerses, Baturin | ||
'''CLAS12 Trigger''' | '''CLAS12 Trigger''' | ||
Sergey B. described Forward Calorimeter cluster finding algorithms used by online and offline reconstruction code. | |||
Features: | |||
- 1. can apply individual gain to channels in FADC board's FPGA | |||
- 2. can do 36 loop, or 36 in parallel | |||
Line 10: | Line 15: | ||
* Dave Heddle implemented new TOF and ST into CED, still working to use SCT banks instead of SC for TOF TDCs | * Dave Heddle implemented new TOF and ST into CED, still working to use SCT banks instead of SC for TOF TDCs | ||
* level2 was evaluated, some stuff fixed, we are trying to comeup with better support scheme, some electronics changes maybe required | * level2 was evaluated, some stuff fixed, we are trying to comeup with better support scheme, some electronics changes maybe required (SECL flexio, ask Ed) | ||
* ''clonmon'' installed, working to open it to outside and setut all necessary software | * ''clonmon'' installed, working to open it to outside and setut all necessary software | ||
* moller-cable was swap; epics alarm was swap, so we did not found problem immediately, Nerses will fix alarm | |||
* L1 about 20kHz, 3 kHz accepted, roc crashes every second day |
Latest revision as of 11:17, 14 November 2007
present: Sergey Boyarinov, Benjamin Raydo, Sergey Pozdnyakov, Stepan, Valery, Nerses, Baturin
CLAS12 Trigger
Sergey B. described Forward Calorimeter cluster finding algorithms used by online and offline reconstruction code. Features: - 1. can apply individual gain to channels in FADC board's FPGA - 2. can do 36 loop, or 36 in parallel
G9A
- epics channel list has been cleaned up
- Dave Heddle implemented new TOF and ST into CED, still working to use SCT banks instead of SC for TOF TDCs
- level2 was evaluated, some stuff fixed, we are trying to comeup with better support scheme, some electronics changes maybe required (SECL flexio, ask Ed)
- clonmon installed, working to open it to outside and setut all necessary software
- moller-cable was swap; epics alarm was swap, so we did not found problem immediately, Nerses will fix alarm
- L1 about 20kHz, 3 kHz accepted, roc crashes every second day