'''CODA''' is DAQ software designed and supported by JLAB CODA group. This section contains some information related to the use of CODA in Hall B. | '''CODA''' is DAQ software designed and supported by JLAB CODA group. This section contains some information related to the use of CODA in Hall B. | ||
== End transition == | |||
Executed in the order opposite to 'Go' transition: TS ROC first, then all remaining ROCs, then EB. | |||
First ROC receives 'End' command: | |||
1. 'coda_roc::codaEnd()' called, it does following: | |||
* call 'ROL1::__end()' routine; it disables triggers and calls 'blocksLeft = tiBReady()' until nothing left, or until timeout | |||
* call 'codaUpdateStatus("ending")', sets 'tcpState = rocp->state = DA_ENDING' and 'rocp->active = 2' | |||
2. inside 'coda_roc::output_proc_network' loop: after exiting current loop iteration execute 'case DA_ENDING': | |||
* make sure the output buffer gets sent if there is any data in it | |||
* make sure we have the last event in the output buffer | |||
* call informEB(EV_END) to send 'End' event to EB | |||
* call codaUpdateStatus("downloaded"), set tcpState = rocp->state = DA_DOWNLOADED | |||
3. In network thread, 'roc_network::net_thread()' loop send 'end' event to EB, see 'ifend' flag in it, break loop, sleep(1), cleanup big buffers, call 'roc_network::LINK_close' which calls 'shutdown(socket, 2)' and 'close(socket)' closing connection to EB | |||
After coda_roc is finished, 'End' command issued to EB, it executes 'coda_eb::codaEnd()', doing following: | |||
1. Checks EB state in database, it should be 'active' (if 'downloaded', do nothing) | |||
2. Building thread(s) see End event, call 'CODA_decode_spec(&temp,desc1)' ... | |||
3. 'coda_eb::polling_routine()' (started as thread by constructor) see 'ebp->ended == 1', canceling building thread(s) and calls 'LINK_support::debCloseLink()' for every connected ROC telling input thread(s) to exit ('''what if they already exited ?''') | |||
4. Wait for building thread(s) to finish and cleanup building threads, then exit 'coda_eb::codaEnd()' (TEMPORARY using 'force_end=1', see code) | |||
5. In a meanwhile, 'LINK_support::debCloseLink()' executed exiting EB input threads (one per ROC) | |||
== VME Controllers: Intel-based FANUC under RHEL OS == | == VME Controllers: Intel-based FANUC under RHEL OS == |
Latest revision as of 18:05, 8 May 2019
CODA is DAQ software designed and supported by JLAB CODA group. This section contains some information related to the use of CODA in Hall B.
End transition
Executed in the order opposite to 'Go' transition: TS ROC first, then all remaining ROCs, then EB.
First ROC receives 'End' command:
1. 'coda_roc::codaEnd()' called, it does following:
- call 'ROL1::__end()' routine; it disables triggers and calls 'blocksLeft = tiBReady()' until nothing left, or until timeout
- call 'codaUpdateStatus("ending")', sets 'tcpState = rocp->state = DA_ENDING' and 'rocp->active = 2'
2. inside 'coda_roc::output_proc_network' loop: after exiting current loop iteration execute 'case DA_ENDING':
- make sure the output buffer gets sent if there is any data in it
- make sure we have the last event in the output buffer
- call informEB(EV_END) to send 'End' event to EB
- call codaUpdateStatus("downloaded"), set tcpState = rocp->state = DA_DOWNLOADED
3. In network thread, 'roc_network::net_thread()' loop send 'end' event to EB, see 'ifend' flag in it, break loop, sleep(1), cleanup big buffers, call 'roc_network::LINK_close' which calls 'shutdown(socket, 2)' and 'close(socket)' closing connection to EB
After coda_roc is finished, 'End' command issued to EB, it executes 'coda_eb::codaEnd()', doing following:
1. Checks EB state in database, it should be 'active' (if 'downloaded', do nothing)
2. Building thread(s) see End event, call 'CODA_decode_spec(&temp,desc1)' ...
3. 'coda_eb::polling_routine()' (started as thread by constructor) see 'ebp->ended == 1', canceling building thread(s) and calls 'LINK_support::debCloseLink()' for every connected ROC telling input thread(s) to exit (what if they already exited ?)
4. Wait for building thread(s) to finish and cleanup building threads, then exit 'coda_eb::codaEnd()' (TEMPORARY using 'force_end=1', see code)
5. In a meanwhile, 'LINK_support::debCloseLink()' executed exiting EB input threads (one per ROC)
VME Controllers: Intel-based FANUC under RHEL OS
CODA group install RHEL OS into flash memory, so it boot after power recycle. Auto mount and some other stuff must be adjusted for clon cluster: