* Ben's trigger GUI is working; v1495 software was adjusted; EPICS scalers readout to be implemented
* Ben's trigger GUI is working; v1495 software was adjusted; EPICS scalers readout to be implemented


* DAQ was tuned; both rol2 and net are running on all available co-processors; 'parallel' rol1 is used everywhere; reached 4.6kHz at 86% livetime, limited by DC occupancy but DAQ limit is close as well; sc2 rol1 processing time is much bigger then others (see xxx); clastrig2 readout speed still to be studied  
* DAQ was tuned; both rol2 and net are running on all available co-processors; 'parallel' rol1 is used everywhere; reached 4.6kHz at 86% livetime and beam current 140nA, limited by DC occupancy but DAQ limit is close as well; sc2 rol1 processing time is much bigger then others (see [https://clonwiki0.jlab.org/wiki/clondocs/Docs/tpe_run_rol1.ps ps]), may try to decrease readout window width; clastrig2 readout speed still to be studied  
 
* fast reconstraction works producing target [https://clonwiki0.jlab.org/wiki/clondocs/Docs/tpe_run_target.ps image].


* RF signal dissapeards, Raffaella fixed it (bad unit, see logbook Dec 14 around 7pm), need to fix permanently
* RF signal dissapeards, Raffaella fixed it (bad unit, see logbook Dec 14 around 7pm), need to fix permanently
Line 15: Line 17:
* two kind of ROC crashes were observed: ROLS_LOOP on host and PROC on PMCs; last one does not require reboot, cancel-reser-download-.. works, first one will try it; will try to reproduce and debug it over downtime (big buffer check function etc)
* two kind of ROC crashes were observed: ROLS_LOOP on host and PROC on PMCs; last one does not require reboot, cancel-reser-download-.. works, first one will try it; will try to reproduce and debug it over downtime (big buffer check function etc)


* TOF SCHV alarm did not work when all values (except EPICS demand values) went to zero; crate turned on but values stayed zero and it was no alarm which is correct; we do not know why values went down
* TOF SCHV alarm did not work when all values (except EPICS demand values) went to zero; crate turned on but values stayed zero and it was no alarm which is correct; we do not know why values went down to zero; will ask Nerses to look
 
* epics_monitor config files are ready and will be installed; run_log_comment and database info to be reviewed and corrected

Latest revision as of 15:06, 17 April 2015

present: Sergey Boyarinov, Sergey Pozdnyakov

1. TPE run status

  • new trigger was commissioned and compared with old one, seems working, need to measure adc gate position; latch feature seems working, need to read it out and place to datastream
  • Ben's trigger GUI is working; v1495 software was adjusted; EPICS scalers readout to be implemented
  • DAQ was tuned; both rol2 and net are running on all available co-processors; 'parallel' rol1 is used everywhere; reached 4.6kHz at 86% livetime and beam current 140nA, limited by DC occupancy but DAQ limit is close as well; sc2 rol1 processing time is much bigger then others (see ps), may try to decrease readout window width; clastrig2 readout speed still to be studied
  • fast reconstraction works producing target image.
  • RF signal dissapeards, Raffaella fixed it (bad unit, see logbook Dec 14 around 7pm), need to fix permanently
  • last night 2 switches went down, CC want to replace the one on 96 subnet, should think about bethsw3sc; also, dc6pmc1 died and did not want to reboot
  • two kind of ROC crashes were observed: ROLS_LOOP on host and PROC on PMCs; last one does not require reboot, cancel-reser-download-.. works, first one will try it; will try to reproduce and debug it over downtime (big buffer check function etc)
  • TOF SCHV alarm did not work when all values (except EPICS demand values) went to zero; crate turned on but values stayed zero and it was no alarm which is correct; we do not know why values went down to zero; will ask Nerses to look
  • epics_monitor config files are ready and will be installed; run_log_comment and database info to be reviewed and corrected