LeCroy 4616 16-Channel ECL/NIM/ECL Converter
OVERVIEW

The Model 4616 is simultaneously an ECL-to-NIM and a NIM-to-ECL
converter, specially designed to fill the gap between the new growing
ECL circuitry and the old NIM electronics. The Model 4616 is designed
so that each channel can be used for both applications. When ECL
complementary pulses have to be converted, the circuit provides three
NIM outputs and an additional ECL output. When a NIM pulse has to be
converted, it is sent in one of the NM outputs (now used as an input)
while the other two NIM outputs are unconnected. Thus, the circuit
provides a single complementary ECL output.
SPECIFICATIONS
Input Characteristics
- ECL Inputs:
- 16, one per section, in a 2 x 17 pin connector; accept
complementary ECL levels; typical threshold 200 mV.
- NIM Inputs:
- 16, one per section, Lemo-type connector, to be chosen
out of the three Lemo-type connectors in the channel; the
other two have to be kept unconnected; input im- pedance 50
Ohm +/- 5%; reflections < 10% for input risetimes > 2
nsec.
Output Characteristics
- ECL Outputs:
- 16, one per section, in a 2 x 17 pin connector; ECL
complementary levels (- 0.8 V and - 1.7 V); risetime 2 nsec
typical.
- NIM Outputs:
- 48, three bridged outputs per section, Lemo-type
connectors; quiescently at 0 mV, > - 700 mV into 3 x 50
Ohm loads, max. - 1.2 V into 1 x 50 Ohm load, during output;
risetime 2 nsec typical.
General
- Maximum Frequency: 150 MHz
- Minimum Pulse Width:
- ECL and NIM inputs/outputs 4 nsec.
- Transit Times:
- ECL input to NIM output <6 nsec.
ECL input to ECL output < 10.5 nsec.
NIM input to ECL output < 6.5 nsec.
- Power Requirements:
- - 6 V quiescently at 700 mA, with all loads connected and
all channels activated max. 1.7 A.