CAEN C469 16-ch Gate And Delay Generator ======================================== CAMAC Commands ~~~~~~~~~~~~~~ F(16) N A(n) Writes the delay time (W1..W8) of the output selected by subaddress. n=0..15. The same output is associated with the two multiplexed outputs ("MUX"). F(17) N A(n) Writes the gate width (W1..W8) of the output selected by subaddress. n=0..15. The same output is associated with the two multplexed outputs ("MUX"). F(18) N A(n) Selects the output to be associated with the two multiplexed outputs ("MUX") of the module connectors. n=0..15. F(19) N A(0) Assigns the set gate and delay values to the corresponding outputs. F(25) N A(0) Generates a TEST signal. F(9) N Resets the module at S1 time. C, Z Resets the module at S2 time. X and Q response for each valid function ----------------------------------------------------- Note: All settings are battery backed-up, so the module does not have to be reprogrammed after a power failure: in this case, only an F(19) N A(0) CAMAC function has to be performed to reassign each stored value to the relevant channel.