Phillips 7126 ECL/NIM/TTL Translator

OVERVIEW

FEATURES

DESCRIPTION

The model 7126 is a 16-channel level translator packaged in a double width CAMAC module. It simultaneously converts in any direction between NIM, TTL and ECL logic families. In addition, a logical "OR" is possible for the ECL input and the NIM/TTL input. The input to output is direct coupled with the output duration equal to the input duration. Each channel has a single input connector which accepts a fast negative NIM level with 50 ohm input impedance and a positive TTL level with 500 ohms impedance. This produces a positive TTL output capable of driving a 50 ohm load and a bridged NIM output that drives two 50 ohm loads. The NIM output stage is current-switching which allows pulse clipping and is protected from damage due to shorted cables.


Input Characteristics

NIM/TTL 16 inputs, one per channel, LEMO style connector:
accepts both negative NIM or positive TTL pulses or levels.
NIM: 50 ohms impedance +/-10%; -500 mV threshold; input protected to +/-8 VDC.
TTL: 500 ohms impedance +/-10%; +1.2 Volt threshold; input protected to +/-8 VDC.
ECL Input 16 inputs, one per channel:
2 x 17 pin header with lock and eject feature; accepts complementary ECL inputs; removable 110 ohm input termination; 200 mV differential threshold.

Output Characteristics

NIM Outputs. Two NIM outputs per channel:
bridged -32 mA current switching, LEMO style connectors; delivers one double amplitude NIM level or two normal NIM levels into 50 ohms; 1.5 nsec rise and fall times.
TTL Output. One TTL output per channel:
LEMO style connector; sources 45 mA to drive 50 ohm load or 1000 standard TTL loads, sink current of 100 mA; able to drive 100 standard TTL loads. 3.5 nsec rise and fall times.
ECL Output. Complementary ECL, one per channel:
2 x 17 pin header with lock and eject feature; drives two 110 ohm ECL loads or up to 30 daisy-chained loads. Normal ECL levels of -800 mV and -1.7 Volts, 2 nsec rise and fall times.

General Characteristics

Rate
DC to 150 MHz for NIM and ECL translation,
DC to 100 MHz for TTL translation.
Minimum 4 nsec for NIM and ECL translation,
Pulse Widths 7 nsec for TTL translation.
Delay
NIM, TTL or ECL input to NIM or ECL output = 5 nsec.
NIM, TTL or ECL input to TTL output = 10 nsec.
Power Requirements:
+ 6V @ 450 mA, - 6V @ 1290 mA
+ 24V @ 110 mA, - 24V @ 110 mA


Download actual Specifications in .PDF format for this model number or go to our Download area where all the data sheets are available and are listed by model number.

Back to the Product Selection Page or the Phillips Scientific Home Page