3660 Programmable Clock Generator

FEATURES

APPLICATIONS

GENERAL DESCRIPTION

The Model 3660 is a single-width CAMAC module providing a very flexible programmable multi-step clock generator for clocking ADCs and other front-end data acquisition modules. It provides a programmable sequence of clock rates for applications requiring different sampling rates during different phases of data collection and the ability to synchronize data sampling with an external trigger as well as dividing down an external clock source.

The 3660 provides storage for sequences as long as 256 steps where the frequency and duration of each step can be programmed. The module derives the output clock from one of three sources: a 10 MHz crystal clock, a 10.24 MHz crystal clock, or an external clock. Each step is defined by a division factor by which the base clock is divided. The duration of each step is determined by an associated count or external trigger. In the case of external trigger, the next step is initiated synchronously with the 2nd tick of the base clock. An optional LAM can be generated at the end of any step to signal the host processor that a new step has been initiated. The current frequency division, current step, amperes count, previous step sample count, and program step address are directly accessible registers.

The frequency steps are loaded by software into the program RAM. Each step includes a base frequency divisor, a step termination selection based on a specified count, external trigger, or software command only, and a flag word that selects various options on a step by step basis. The frequency divisor is a 16-bit modulo-N value by which the base frequency is divided. This provides a frequency range from 152.59 Hz to 10 MHz range for the 10 MHz base clock. For low frequency applications, the base clock divided by 256 may be selected providing frequency ranges of 0.5961 Hz to 39.062 KHz (10 MHz base clock) or 0.6104 Hz to 40.0 KHz (10.24 MHz base clock). The count field is a 24-bit count that permits from 1 to 16 Msamples per step. When external trigger is selected, these bits are used to select a trigger divisor. A value of 4 would for example terminate the step on the 4th trigger.

The module is also capable of generating the following signals at the completion of a step:

In addition the module can selectively set or clear a TTL level signal at the start of each step. This signal is available on the Gate-Out LEMO connector on the front panel and can be selected to drive the CAMAC Inhibit line.

The following control options are associated with each program step:

The base clock frequency is selected by bits in the CSR register.

A previous pulse count register is provided that is loaded with the current sample count at the end of each step and is accessible hy CAMAC command. This register can be read following a step to determine the number of samples from the previous step. Thus, the actual number of samples acquired during a step which was terminated by an external trigger or CAMAC command, can be determined.

POWER REQUIREMENTS

+6 volts — 2.1 A

Weight: .62 kg. (1 lb. 6 oz.)

ORDERING INFORMATION

Model 3660-Z1A — Programmable Clock Generator (10.24 MHz maximum)

Accessories:

Model 5910-Z1A Single-pin LEMO Connector

Model 5857-Bxyz 1-pin LEMO/RG174/1-pin LEMO Cable Assembly