Conclusion
¥All high-resolution TDCs in CLAS are pipeline multihit boards
¥CLAS front-end busy is fixed 12us (defined by Lecroy 1881 ADCs) which makes it possible to increase event rate up to 10kHz at dead time below 15%
¥In general we were satisfied with service provided by commercial companies: WIENER service (VME64X crates) was very good; CEAN service was good but several iterations of sample boards and firmwire upgrades were needed to get required parameters; following support from both companies was very good
¥Better coordination is required in future to keep our schedule in sync with other Hall B and JLAB groups
¥