<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://clonwiki0.jlab.org/wiki/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=129.57.49.93</id>
	<title>CLONWiki - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="https://clonwiki0.jlab.org/wiki/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=129.57.49.93"/>
	<link rel="alternate" type="text/html" href="https://clonwiki0.jlab.org/wiki/index.php?title=Special:Contributions/129.57.49.93"/>
	<updated>2026-04-11T03:08:38Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.42.1</generator>
	<entry>
		<id>https://clonwiki0.jlab.org/wiki/index.php?title=BONUS_Readout&amp;diff=4491</id>
		<title>BONUS Readout</title>
		<link rel="alternate" type="text/html" href="https://clonwiki0.jlab.org/wiki/index.php?title=BONUS_Readout&amp;diff=4491"/>
		<updated>2009-09-23T18:23:45Z</updated>

		<summary type="html">&lt;p&gt;129.57.49.93: /* connections */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;This page contains information related to the BONUS TPC chamber readout system.&lt;br /&gt;
&lt;br /&gt;
== History ==&lt;br /&gt;
&lt;br /&gt;
 From:  Stephen Bueltmann &amp;lt;sbueltma@odu.edu&amp;gt; 11/30/07 14:48&lt;br /&gt;
 Subject:  Fwd: RORC and DDL Information&lt;br /&gt;
 To: &lt;br /&gt;
        Sergey Boyarinov &amp;lt;boiarino@jlab.org&amp;gt;, David Abbott &amp;lt;abbottd@jlab.org&amp;gt;,&lt;br /&gt;
        Stepan Stepanyan &amp;lt;stepanya@jlab.org&amp;gt;, Howard Fenker &amp;lt;hcf@jlab.org&amp;gt;, hafidi@jlab.org&lt;br /&gt;
 Hello All,&lt;br /&gt;
 I am attaching a reply I received from the Hungarian company manufacturing the  &lt;br /&gt;
 ALICE (not the TPC) side of the electronics.&lt;br /&gt;
 As per their web site (http://www.cerntech.hu) the price for the&lt;br /&gt;
 PCI-X RORC is 1540 Euro and for one&lt;br /&gt;
 SIU card 615 Euro. &lt;br /&gt;
 The total would be 2770 Euro for a complete readout w/o RCU and w/o spares.&lt;br /&gt;
 There seem to be special prices for CERN collaborating institutions.&lt;br /&gt;
 Wrote to Luciano about the RCU boards but have not heard back.&lt;br /&gt;
 Cheers,&lt;br /&gt;
    Stephen &lt;br /&gt;
 Begin forwarded message:&lt;br /&gt;
 From: &amp;quot;Kiss Tivadar&amp;quot; &amp;lt;tivadar.kiss@cerntech.hu&amp;gt;&lt;br /&gt;
 Date: November 30, 2007 2:35:36 PM EST&lt;br /&gt;
 To: &amp;quot;&#039;Stephen Bueltmann&#039;&amp;quot; &amp;lt;sbueltma@odu.edu&amp;gt;&lt;br /&gt;
 Subject: RE: RORC and DDL Information&lt;br /&gt;
 Dear Stephen,  &lt;br /&gt;
 We are pleased to receive your inquiry for DDL hardware. Of course it is possible for you to get such boards from our company. Delivery time would be cca. 1-3&lt;br /&gt;
 monthes after receiving an order, depending on the quantity. (We have usually only a few cards on stock.)&lt;br /&gt;
 The DIU (Destination Interface Unit) of a DDL link is now integrated on the RORC (Read-out Receiver Card). A single RORC (that is 100 MHz, 64-bit&lt;br /&gt;
 PCI-X interaface card) has two DIUs integrated on it. Thus, for two DDL links (that is, to read out two ALICE RCUs) you need 2 SIU cards and 1 RORC card.&lt;br /&gt;
 Please let me know how many quantities you are interested in, and what is a delivery schedule that would fit to your needs. &lt;br /&gt;
 Best regards, &lt;br /&gt;
   Tivadar Kiss&lt;br /&gt;
 Cerntech Ltd. &lt;br /&gt;
 Ulloi ut 31.&lt;br /&gt;
 H-1091 Budapest&lt;br /&gt;
 Hungary&lt;br /&gt;
 tel: +36 1 216 8219)&lt;br /&gt;
 fax: +36 20 919 5132&lt;br /&gt;
      From: Stephen Bueltmann [mailto:sbueltma@odu.edu] &lt;br /&gt;
      Sent: Thursday, November 29, 2007 4:05 PM&lt;br /&gt;
      To: info@cerntech.hu&lt;br /&gt;
      Subject: RORC and DDL Information&lt;br /&gt;
      Hello, &lt;br /&gt;
      I am involved with the experimental programme at Jefferson Lab&lt;br /&gt;
      in the US. One of the experiments is using a TPC which we are&lt;br /&gt;
      reading out with the ALICE TPC front end cards FECs and their&lt;br /&gt;
      USB readout controller (U2F).&lt;br /&gt;
      We are considering to change to the standard ALICE readout controller &lt;br /&gt;
      (RCU) used by the ALICE TPC.&lt;br /&gt;
      This would require to purchase also the RORC and DDL hardware.&lt;br /&gt;
      Would it be possible and how long would it take to get one RORC, one&lt;br /&gt;
      SIU and one DIU card from you?&lt;br /&gt;
      Thanks in advance and&lt;br /&gt;
      Cheers,&lt;br /&gt;
      Stephen&lt;br /&gt;
      ---------------------------------------------------------------------&lt;br /&gt;
      Stephen Bueltmann&lt;br /&gt;
      Old Dominion University&lt;br /&gt;
      At ODU:   Physics Department&lt;br /&gt;
                4600 Elkhorn Avenue&lt;br /&gt;
                Norfolk, VA 23529, USA&lt;br /&gt;
                Telephone (757) 683-6401&lt;br /&gt;
                Facsimile (757) 683-5809&lt;br /&gt;
                sbueltma@odu.edu&lt;br /&gt;
      ----------------------------------------------------------------------&lt;br /&gt;
      ---------------------------------------------------------------------&lt;br /&gt;
      Stephen Bueltmann&lt;br /&gt;
      Old Dominion University&lt;br /&gt;
      At ODU:   Physics Department&lt;br /&gt;
          4600 Elkhorn Avenue&lt;br /&gt;
          Norfolk, VA 23529, USA&lt;br /&gt;
          Telephone (757) 683-6401&lt;br /&gt;
          Facsimile (757) 683-5809&lt;br /&gt;
          sbueltma@odu.edu&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Sep 2009 NOTES for the system operations ==&lt;br /&gt;
&lt;br /&gt;
* firmware loading:&lt;br /&gt;
 from croctest5: ssh root@10.1.3.241 (bottm crate, top has .236), pass is &#039;dcs&#039;&lt;br /&gt;
 cd /eg6&lt;br /&gt;
 ./program rcu_170809.bit&lt;br /&gt;
&lt;br /&gt;
* documentation&lt;br /&gt;
&lt;br /&gt;
 http://www.ge.infn.it/~minutoli/BONUS/SW/&lt;br /&gt;
&lt;br /&gt;
 http://www.jlab.org/~devita/eg6/&lt;br /&gt;
&lt;br /&gt;
* event size (spars off, 200 threshold - no noise): 68+4+128+Nfecs&lt;br /&gt;
&lt;br /&gt;
* expected rate about 1.3kHz&lt;br /&gt;
&lt;br /&gt;
== connections ==&lt;br /&gt;
&lt;br /&gt;
* every crates is connected to 4 power supplies, one 4.0V and 3 3.3V&lt;br /&gt;
&lt;br /&gt;
* several crates can be connected to the same power supplies&lt;br /&gt;
&lt;br /&gt;
* + or - labels must be ignored, rad cable always goes to plus&lt;br /&gt;
&lt;br /&gt;
* ethernets from crates goes to switch, switch is connected to the eth1 of the host machine; those connections will be used to load firmware; to get IP address crates must be off, use &#039;tail -f /var/log/messages&#039; and turn crate on, message will be issued containing&lt;br /&gt;
IP address; first 2 crates: 10.1.3.241 (with cards), 10.1.3.236 (empty)&lt;br /&gt;
&lt;br /&gt;
* to download firmware ssh root@10.1.3.241 (etc) with password &#039;dcs&#039;, goto &#039;&#039;/eg6&#039;&#039; and run command &#039;&#039;./program rcu_170809.bit&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
* fibers goes from crates to RORCs; to see if RORCs are configured by Linux, use &#039;&#039;/date/rorc/Linux/rorc_find&#039;&#039;; to check connection use http://www.jlab.org/~devita/eg6/eg6_electronics.pdf&lt;br /&gt;
&lt;br /&gt;
* to check FECs use command:&lt;br /&gt;
 /rcufec/altro-loopback/altro-loopback -N -p0 -f0 -a5 -c8 --ddl-revision=4 --ddl-channel=1 --ddl-serial=7165&lt;br /&gt;
&lt;br /&gt;
output should looks like this&lt;br /&gt;
 Switching on FEC 0...done.&lt;br /&gt;
 Writing data to ALTROs for event: 1...2...3...4...done.&lt;br /&gt;
 Reading data from ALTROs for event: 1...354 words, 2...355 words, 3...355 words, 4...355 words, done.&lt;br /&gt;
 Verifying event: 1...2...3...4...done.&lt;br /&gt;
 Switching off FEC 0...done.&lt;br /&gt;
&lt;br /&gt;
* to check real communications do following:&lt;br /&gt;
&lt;br /&gt;
 cd /rcufec/fec&lt;br /&gt;
 ./fecscope&lt;br /&gt;
 2&lt;br /&gt;
 1,1 (rorc channel number)&lt;br /&gt;
 3,0,0&lt;br /&gt;
 3,0,3(the number of FECs),0,1,2&lt;br /&gt;
 10,100,0,0,1/6&lt;br /&gt;
&lt;br /&gt;
 cd /date/rorc/Linux&lt;br /&gt;
 ./rorc_receive -m0 -X0 -c1 -e1&lt;br /&gt;
 it will wait for 1 event, to issue software trigger ssh root@10.1.3.241 and type &#039;&#039;rcu-sh c 0x5306&#039;&#039;&lt;/div&gt;</summary>
		<author><name>129.57.49.93</name></author>
	</entry>
</feed>